Bowers-group UniCal Universal Digital Caliper Instrukcja Użytkownika Strona 64

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 72
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 63
64
6464
64
VII.1 Deactivate the message "Error"
Press [set] to restart the measurement.
Don't forget to check the instrument’s origin.
VIII Use with half duplex adapter
VIII.1 Modes of use
Simplex mode: enables the instrument to be polled from the computer (i.e. footswitch or request by periphery).
Duplex mode: enables the instrument to be polled by the computer and provides for 2 way communication to allow use of the instrument transmit button. The
instrument and other half duplex devices cannot receive and transmit data simultaneously.
VIII.2 How to connect the OPTO-RS cable
Check the way you plug the connector in.
If you plug it wrong, no damage will result but it simply won’t work.
VIII.3 Transmission parameters
4800 Bauds, even parity, 7 ASCII bits, 2 stop bits
VIII.4 Use of the simplex mode, without half duplex adapter
The data output can be initiated by quick press on the [set] button in the following modes:
- references
- minmax
- tolerances
Przeglądanie stron 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 70 71 72

Komentarze do niniejszej Instrukcji

Brak uwag